Back to Top

Hi, Guest!

  LOKASI :  Kota Depok

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Milwaukee - Mi 170

Milwaukee - Mi 170

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
2 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Milwaukee - Mi 170

Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter Mi170 measures 4 different parameters - EC, TDS ( Total Dissolved Solids) , percentage of NaCl and temperature in a variety of ranges. The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25° C and the compensation coefficient is selectable by the user. The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 or USB port. SPECIFICATION : EC Range : 0.00 to 29.99 µ S/ cm; 30.0 to 299.9 µ S/ cm; 300 to 2999 µ S/ cm; 3.00 to 29.99 mS/ cm; 30.0 to 200.0 mS/ cm; up to 500.0 mS/ cm actual Conductivity* TDS Range : 0.00 to 14.99 mg/ l ( ppm) ; 15.0 to 149.9 mg/ l ( ppm) ; 150 to 1499 mg/ l ( ppm) ; 1.5 to 14.99 g/ l ( ppt) ; 15.0 to 100.0 g/ l ( ppt) ; up to 400.0 g/ l actual TDS* ( with 0.80 factor) NaCl Range : 0.0 to 400.0% Temp Range : -20.0 to 120.0° C / -4.0 to 248.0° F EC Resolution : 0.01 µ S/ cm; 0.1 µ S/ cm; 1.0 µ S/ cm; 0.01 mS/ cm; 0.1 mS/ cm TDS Resolution : 0.01 mg/ l; 0.1 mg/ l; 1.0 mg/ l; 0.01 g/ l; 0.1 g/ l NaCl Resolution : 0.1% Temp Resolution : 0.1° C / 0.1 ° F EC Accuracy : ± 1% of reading ± ( 0.05 µ S/ cm ro 1 digit) TDS Accuracy : ± 1% of reading ± ( 0.03 mg/ l or 1 digit) NaCl Accuracy : ± 1% of reading Temp Accuracy : ± 0.4° C / ± 0.8° F EC Calibration : 1 point slope calibration with 6 memorized solutions ( 84.0 µ S/ cm, 1413 µ S/ cm, 5.00 mS/ cm, 12.88 mS/ cm, 80.0 mS/ cm, 111.8 mS/ cm) NaCl Calibration : 1 point, with MA9066 calibration solution Temp Calibration 2 points, 0 to 50° C / 32 to 12 ° F Temp. Compensation automatic or manual, : from -20.0 to 120.0° C / -4.0 to 248.0° F Temp. Coefficient : selectable from 0.00 to 6.00% / ° C ( EC and TDS only) Probe : MA813D/ 1 4-ring probe with built-in temperature sensor ( included) TDS Factor : 0.40 to 0.80 ( default value is 0.50) Log on Demand : up to 50 samples on each range ( EC, TDS, NaCl)
Tampilkan Lebih Banyak