Detail THERMAL IMAGER FLUKE TI100
Detailed Specifications
IR resolution ( FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 µ m to 14 µ m ( long wave)
Capture or refresh rate 9 Hz
NETD ( Thermal sensitivity) d0.10 ° C at 30 ° C target temp ( 100 mK)
FOV ( Field of view) 22.5 ° H x 31 ° V
IFOV ( Spatial resolution) 3.39 mRad
Temperature measurement range ( not calibrated below -10 ° C)
-20 ° C to + 250 ° C
( -14 ° F to 482 ° F)
Temperature measurement accuracy ± 2 ° C or 2 % ( at 25 ° C nominal, whichever is greater)
Focus mechanism Focus-free 1.2 m ( 4 ft) and beyond
IR Fusion ® technology No, full IR only
CNX wireless enabled Yes
Color alarms —
Standard palettes Blue-Red, Ironbow, Grayscale, Amber
Ultra Contrast™ palettes —
Hot/ cold markers —
User definable spot markers in SmartView® only
Centerbox ( MIN/ AVG/ MAX) —
Level and span control Manual and auto
Minimum span in auto mode 5 ° C
Minimum span in manual mode 2.5 ° C
Minimum IR focus distance 1.2 m ( 4 ft)
Weight 0.726 kg ( 1.6 lb)
Size 28.4 x 8.6 x 13.5 cm ( 11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal ( portrait format)
Visible camera N/ A
Minimum parallax N/ A
IR-PhotoNotes™ annotation system —
Laser pointer Yes
Torch —
Electronic ( cardinal) compass —
Emissivity correction Yes
Transmission correction —
Background ( reflected) compensation Yes
Voice annotation ( audio) —
Multi-mode video output —
Multi-mode video recording ( standard AVI with MPEG encoding) —
Multi-mode video recording ( radiometric .IS3) —
Memory review thumbnail review
Battery ( field-replaceable, rechargeable) One
Battery life 4+ hours ( each) *
External battery charging base Optional ( accessory)
Charging power supply Yes
Drop test 2 meter ( 6.5 feet)
Ingress protection ( IP) rating ( IEC 60529) IP 54
Est. calibration cycle Two-years
Multifunction card reader —
Memory storage 2 GB SD memory card
Direct download capability mini USB direct download
Operating temperature range -10 ° C to + 50 ° C ( 14 ° F to 122 ° F)
Storage temperature range -20 ° C to + 50 ° C ( -4 ° F to 122 ° F)
Operating humidity Operating and storage 10 % to 95 % , non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards IEC 61010-1: Cat None, Pollution degree 2
C Tick IEC/ EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes
Tampilkan Lebih Banyak