  • FLUKE
  • Clamp Meter, Tang Amper True RMS FLUKE 353, FLUKE 355

Clamp Meter, Tang Amper True RMS FLUKE 353, FLUKE 355

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
16 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Clamp Meter, Tang Amper True RMS FLUKE 353, FLUKE 355

Fluke 355 and 353 True-rms 2000 A Clamp Meters Electrical specifications : Current measurement dc and ac 10 Hz to 100 Hz Range : 40 A Resolution: 10 mA Accuracy, A: 1.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF: 2.50 A Trigger Level for Hz Filter ON: 0.50 A Range : 400 A Resolution: 100 mA Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF: 2.5 A Trigger Level for Hz Filter ON: 2.5 A Range : 2000 A; 1400 ac rms Resolution: 1 A Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF: 8 A Trigger Level for Hz Filter ON: 8 A Crest Factor ( 50/ 60 Hz) Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A Current measurement ac 100.1 Hz to 1 kHz Range : 40 A Resolution: 10 mA Accuracy > 10 A : 3.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF : 2.50 A Trigger Level for Hz Filter ON : 0.50 A Range : 400 A Resolution: 100 mA Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF : 2.5 A Trigger Lever for Hz Filter ON : 2.5 A Range : 2000 A; 1400 ac rms Resolution: 1 A Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF : 8 A Trigger Level for Hz Filter ON : 8 A Voltage measurement ( 355 only) dc and ac 10 Hz to 100 Hz ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range : 4 V Resolution: 1 mV Accuracy: 1 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V Range : 40 V Resolution: 10 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V Range : 400 V Resolution: 100 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Range : 600 V ac rms Resolution: 1 V Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Range : 1000 V dc Resolution: 1 V Accuracy: 1 % rdg + 5 digits Voltage measurement ( 355 only) ac 100.1 Hz to 1 kHz ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range: 4 V Resolution: 1 mV Accuracy: 3 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V Range: 40 V Resolution: 10 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V Range: 400 V Resolution: 100 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Range: 600 V ac rms Resolution: 1 V Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Ohms measurement ( 355 only) Range: 400 & Resolution: 0.1 & Accuracy: 1.5 % + 5 digits Range: 4 k& Resolution: 1 & Accuracy: 1.5 % + 5 digits Range: 40 k& Resolution: 10 & Accuracy: 1.5 % + 5 digits Range: 400 k& Resolution: 100 & Accuracy: 1.5 % + 5 digits Continuity beeper ( 355 only) On at d 30 & Off at e 100 & Frequency measurement Measurement range : 5.0 Hz to 1 kHz Resolution : 0.1 Hz ( 15 Hz to 399.9 Hz) ; 1 Hz ( 400 Hz to 1 kHz) Accuracy – 5.0 Hz to 100 Hz : 0.2 % + 2 counts Accuracy – 100.1 Hz to 1 kHz : 0.5 % + 5 counts Trigger level : Refer to current and voltage tables
Tampilkan Lebih Banyak