Detail Clamp Meter, Tang Amper True RMS FLUKE 353, FLUKE 355
Fluke 355 and 353 True-rms 2000 A Clamp Meters
Electrical specifications :
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A
Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A
Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor ( 50/ 60 Hz)
Range : 40 A
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A
Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms
Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A
Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A
Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Lever for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement ( 355 only) dc and ac 10 Hz to 100 Hz
( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V
Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V
Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V
Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement ( 355 only) ac 100.1 Hz to 1 kHz ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V
Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V
Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V
Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms
Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement ( 355 only)
Range: 400 &
Resolution: 0.1 & Accuracy: 1.5 % + 5 digits
Range: 4 k&
Resolution: 1 & Accuracy: 1.5 % + 5 digits
Range: 40 k&
Resolution: 10 & Accuracy: 1.5 % + 5 digits
Range: 400 k&
Resolution: 100 & Accuracy: 1.5 % + 5 digits
Continuity beeper ( 355 only)
On at d 30 &
Off at e 100 &
Frequency measurement
Measurement range : 5.0 Hz to 1 kHz
Resolution : 0.1 Hz ( 15 Hz to 399.9 Hz) ; 1 Hz ( 400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz : 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz : 0.5 % + 5 counts
Trigger level : Refer to current and voltage tables
Tampilkan Lebih Banyak